Harwood
Engineering Company, Inc.
Manganin
Cells
-
200,000 PSI Service
-
Metric units to 14,000 BAR or 14,000 Kg/cm2
-
10-point secondary standard calibration traceable to NIST
-
10-point primary standard calibration is available
-
Cells are available for both polar and non-polar fluids
-
Digital panel meters for pressure indication
and/or control
-
4 or 5 digital resolution provides accuracies to +/- 0.05% span
The Harwood Manganin cells are manufactured with carefully temperature-seasoned
Manganin wire and are pressure-seasoned to 300,000 psi. The cells have
an active pressure-measuring coil with a resistance of 120 ohm +/- 0.1
ohm. The remainder of the full bridge circuit is made up of precision wire
wound +/- 0.01% resistors. The pressure sensitivity of the wire is 1.54
x 10-7 ohms per ohm per psi. Each cell is tested and calibrated
before shipment.
One unit is offered to use with high pressure fluids which may be polar
(conducting). In this cell the active coil is isolated from the pressure
fluid, being placed within a bronze bellows which is vacuum filled with
a non-polar high pressure fluid.
The other unit is offered for use with non-polar,
non-hygroscopic, and dry (no water) gases and liquids. This cell is built
into a Harwood 12H, 3M, or 5M series Tee or Cross, and is directly exposed
to the high pressure fluid.
Open coil transducers for
use with non-conductive fluids:
|
Part Number
|
Pressure Range
|
Configuration
|
|
C-7185
|
0 - 200,000 psi
|
12H / 4L x 12H / 4L x Manganin Tee
|
|
C-7186
|
0 - 200,000 psi
|
12H / 4L x Manganin x 12H / 4L
|
|
C-7187
|
0 - 200,000 psi
|
12H / 4L x 12H / 4L x 12H / 4L x Manganin Cross
|
|
C-7181
|
0 - 200,000 psi
|
3M x 3M x Manganin Tee
|
|
C-7182
|
0 - 200,000 psi
|
3M x 3M x 3M x Manganin Cross
|
|
C-7183
|
0 - 150,000 psi
|
5M x 5M x Manganin Tee
|
|
C-7184
|
0 - 150,000 psi
|
5M x 5M x 5M x Manganin Cross
|
|
C-7180
|
0 - 100,000 psi
|
12H / 4L Manganin Coupling
|
* Accuracy is +/- 100 psi. Expected accuracy when calibrated with the Harwood's
instrumentation.
A ten-point NIST traceable calibration is included in the price
of every systems and a calibration certificate is provided.
Jacketed transducers for use
with conductive (water based) fluids:
|
Part Number
|
Pressure Range
|
Configuration
|
|
D-4211-B
|
0 - 200,000 psi
|
12H Connection
|
|
D-4211-B
|
0 - 100,000 psi
|
12H Connection or Optional
4L Pocket & Mounting Bracket
|
* Accuracy is +/- 100 psi. Expected accuracy when calibrated with the Harwood's
instrumentation.
A ten-point NIST traceable calibration is included in the price
of every system and a calibration certificate is provided.
Harwood Engineering Company, Incorporated – © May, 1999
455 South Street, Walpole, Massachusetts 02081
phone: 508-668-3600
fax: 508-660-2276
http://www.ultranet.com/~harwood/
email: harwood@ma.ultranet.com