GoTo HomePageHarwood Engineering Company, Inc.

Safety Assemblies

For Pressures to 220,000 psi

Rupture tube and rupture disk safety assemblies are used to release excessive pressure in case of an emergency, when the system's relief or release pressure valves have failed. It is usually the "last line of defense" in any high pressure system. The burst pressure should be about 10-15% higher than the maximum pressure of the system. The tolerance of the burst is ±5%.

Features

Options


Rupture Tube Safety Assemblies (to 220,000 psi)

 
 
 
 
Dimensions, inches
Pressure Rating, psi*
Inlet Port**
Release Port, NPT
Part #
L
D (Diameter)
150,000
2M
¼ - 18
C-7203
8 7/8
1 ¾
220,000
3M
¼ - 18
C-5998
8 7/8
1 ¾
150,000
5M
¼ - 18
C-6106
9 ¼
1 ¾
150,000
6M
¼ - 18
C-7204
9 ¼
1 ¾
100,000
4L
¼ - 18
C-8789
6 ¼
1 ½
60,000
6L
¼ - 18
C-7206
9 ¼
1 ¾
100,000
8L
¼ - 18
C-7205
9 ¼
1 ¾
60,000
9L-3
¼ - 18
C-6465
10 ¼
2 3/8
220,000
12H-1
¼ - 18
C-5880
9 ¼
1 ¾
*Pressure rating applies to the outlet port
**High pressure ports per Harwood Engineering standard

Rupture Disk Safety Assemblies (to 125,000 psi)

 
 
 
 
Dimensions, inches
Pressure Rating, psi*
Inlet Port**
Release Port, NPT
Part #
L
D (Diameter)
125,000
4L
½ - 14
C-4259
5 15/16
3
60,000
6L
½ - 14
C-4260
5 15/16
3
125,000
8L
½ - 14
C-4261
5 15/16
3
60,000
9L-3
½ - 14
C-4262
5 15/16
3
20,000
9L-5
½ - 14
C-4247
6 9/16
3 ¾
125,000
5M
½ - 14
C-4246
6 7/16
3
125,000
6M
½ - 14
C-4246
6 7/16
3
60,000
15F
½ - 14
C-4258
7 1/8
3 ¾
125,000
16F
½ - 14
C-4263
6 11/16
3
60,000
24F
½ - 14
C-4257
7 1/8
3 ¾
*Pressure rating applies to the outlet port
**High pressure ports per Harwood Engineering standard

Harwood Engineering Company, Incorporated – © May, 1999
455 South Street, Walpole, Massachusetts 02081
phone: 508-668-3600
fax: 508-660-2276
http://www.ultranet.com/~harwood/
email: harwood@ma.ultranet.com